Guide

Laboratory information system checklist, from order to released result

Before choosing a laboratory information system (LIS), check that it follows every test along one path: the doctor's order, the sample and its label, result entry and review, release by an authorised person, and delivery to the doctor, the patient and the invoice. Then check three things around that path: billing and insurance, reagent stock, and the lab manager's reports.

Last reviewed:

In this guide

This laboratory information system checklist suits a laboratory inside a hospital or a medical complex, and a stand-alone lab that takes walk-in patients and referred samples. Ask to see each item on screen in the vendor demo.

An LIS is also sold as medical lab software. For a laboratory information system in Saudi Arabia, the billing section adds two local points: insurance and e-invoicing. The path is drawn step by step on the laboratory information system page.

What path should the system cover, from order to result?

Ask one question: can I tell, at any moment, where each test stands? Each station on the path should record who did it and when: order, collection, receipt in the lab, result entry, review and release, delivery.

  • Order source: the doctor orders inside the visit, and nothing is retyped in the lab.
  • Tests and panels: each order carries a priority (routine, urgent) that travels with it to the sample.
  • Hold and cancel: with a recorded reason, and a warning when the same test is ordered twice.

How should the system handle samples and labels?

A mistake made before analysis, such as the wrong name or the wrong tube, cannot be fixed by any analyser.

  • Barcode label: printed at collection with the patient name, file number, sample type and time. Is it scanned at receipt and at analysis?
  • One sample, several tests: does the system know which orders share a tube and which need another?
  • Collection details: sample type, container, site, who collected it and when.
  • Rejection: a reason picked from a list, and a new collection recorded on the same order.

How are results entered and reviewed?

  • From analyser to system: a direct connection, a file import, or typing by hand? Ask for a written list of your analysers the vendor has already connected.
  • Reference range: next to the value, by sex and age. Is the range in force on the day of the result stored with it?
  • Flags: out-of-range values flagged, critical values flagged differently, with a record of who was told and when.
  • Review and quality control: does a second person check each result, with the patient's previous result next to it? Are control results recorded in the system?

The system flags values. It does not interpret a result: that stays with the laboratory specialist and the doctor.

Who releases a result, and what happens when it changes?

Release is the moment a result becomes visible outside the lab, so it should be a defined permission, not a habit.

  • Separate roles: who enters, who reviews, who releases. Can the same person be stopped from entering and releasing a result?
  • Nothing shows before release: to the doctor or the patient.
  • Changes after release: a written reason, the earlier version kept, and the doctor told.
  • Audit trail: who entered, reviewed, released and changed, and when.

How do results reach the doctor and the patient?

To the doctor. In the patient file, inside the visit the test was ordered from, with an alert for an urgent or critical result and a trend of the same analyte across visits.

To the patient. A report in Arabic and English with the collection and release times and who released it. If results go out as a link, ask how the system checks who opens it.

Privacy. Test results are sensitive health data. Ask which staff can see them, and whether the system logs who opened a file.

How does the system handle billing and insurance?

  • A price list item per test: so no test leaves without an invoice. Ask how a panel is priced against its single tests.
  • Cash patients: is payment required before collection, and what happens to the invoice when a test is cancelled?
  • Patient and insurer shares: on each test, with the approval status, and the same test stopped from being claimed twice.

For insured patients, NPHIES describes itself as a digital gateway that facilitates and governs the exchange of health transactions between the parties of the health sector, with services for checking a beneficiary's eligibility and obtaining prior approvals from the insurer before the service. Ask to see both requests leave from inside the system, and read NPHIES claim rejection reasons.

ZATCA defines an electronic invoice as a tax invoice generated in a structured electronic format through electronic means, and states that the integration phase started on 1 January 2023 in waves. Ask whether the lab's invoice is issued in that format from the same system.

How does it track reagents and consumables?

A reagent that runs out or expires stops the test.

  • Lot, expiry and reorder level: per reagent, with a warning before expiry and at the reorder level.
  • Consumption per test: does stock go down with each test, and how are controls, calibrations and repeat runs counted?
  • Purchasing and accounts: if stock lives in another program, receipts and issues are entered twice. See what gets lost between the clinic system and the accounting program.

Which reports does the lab manager need?

  • Pending now: samples not collected or not received, results entered and not released, orders open from earlier days.
  • Turnaround time: by test and priority. Ask which two moments it is counted between.
  • Rejected samples: by reason, collection point and collector.
  • Workload and revenue: by test, section, technician, insurer and referring doctor.

What should you ask the vendor in the demo?

Copy this table and add a column per vendor: yes, partly or no.

ItemAsk to see on screen
OrderA doctor ordering an urgent panel from the visit
LabelA barcode label printed, then scanned at receipt
RejectionA sample rejected with a reason, then collected again
AnalysersA result moving from an analyser into the system
Reference rangeAn out-of-range value and a critical value
ReleaseA user without permission stopped from releasing
AmendmentA released result changed, with the reason kept
DeliveryThe result in the doctor's visit, and the patient report
InvoiceA cash test, and an insured test with the patient share
StockA reagent balance going down, and an expiry warning

Off screen, ask:

How Nixpend helps

In Nixpend the doctor orders a test or a panel from the visit and sets its priority. The sample is recorded with its type, container, who drew it and when, and a barcode ties the tube to its orders. The lab receives it or rejects it with a recorded reason. Results show next to the normal range with out-of-range and critical values flagged, and the doctor sees them only after the lab releases them. Each test is tied to a price list item and enters the invoice with the patient share, the insurer share and the approval status. See the laboratory page, or book a demo.

FAQ

What is the difference between an LIS and the facility's health information system?

The LIS runs the test path: sample, result and release. The facility's system runs the file, the visit and the invoice. When they are one system, nobody types the order or the result twice.

Is medical lab software without an analyser connection enough for a small lab?

It can be, while test numbers are low and a second person reviews every result typed by hand. As volume grows, ask about analyser connections.

How do I measure turnaround time?

Fix the start and end points, for example from sample receipt to result release, then ask for the report by test and priority.

See Nixpend on a day like yours

A 30-minute walk through the platform, on a scenario close to your day: from the booking to the claim and the journal entry.